Programming and management of up to two independent heating stations, consisting of: CEIA Power Cube Generator; CEIA SH/SLE series non-contact temperature sensor or external thermocouples; automatic solder dispenser; antioxidant gas diffuser
High-definition graphic display
Internal memory and removable SDC Card containing up to 100 work programs
Multiple interface Capability including: Industrial current/voltage I/O; Field Bus; RS-232; up to 22 input and 22 output
Validation and Reporting of each heating cycle for Production Quality Control and Certification
“STATUS” key for immediate reading of main Generator working parameters
“QUICK ACCESS” key for fast programming of user defined parameters
For more than 30 years CEIA has been manufacturing Generators and Control units for induction heating processes characterized by very high efficiency and minimum operating costs. CEIA’s unique technological solutions allow the manufacturing of power equipment with compact size, extremely high-energy efficiency and long-term reliability.
Thanks to the experience achieved in the field, and to the continuous R&D activities, CEIA is now proud to introduce the Master Controller V3+.
The Standard Controller version comes with a set of predefined programs. All operating parameters for each phase of the heating cycle can be programmed within a wide range of values.
This allows maximum flexibility in setting the heating and cooling times, the power supplied by the induction generators, the operating temperatures for the piece being worked on and the quantity and feed speed of the soldering wire.
A wide range of digital and analog I/O signals, a fieldbus and an RS-232 serial interface allow connection to PLC, PC or external logic for remote loading and running of preset and user-defined heating programs.
The isolated inputs have programmable P/N logic, while the isolated outputs use a programmable auxiliary voltage of 12/24 V.
Heating system set-up
Alternating between the two heads (if connected to a single Power Cube generator)
Simultaneously on two heads (if connected to two Power Cube generators)
Capable of driving Power Cube generators in continuous operation
Management and Control
Activation of cycle: via external contact, RS-232 or Fieldbus interface
Control and Time Programming of 2 antioxidant gas diffusers, 2 heating heads and 2 wire dispensers
Available Settings: heating power; heating temperature (resolution 0,1°C); wire quantity and speed; antioxidant gas supply times; maximum solder force; wire feeder; piston advance delay
Control of the temperature of the article being processed: via optical temperature sensors, thermocouple or external sensors
SH15/SLE sample rate: 0.5 milliseconds
SH15/SLE time constant: 0.1 milliseconds
Functioning Modes
Manual
TIMER A: fully time-programmable cycle phases with controlled-temperature holding time
TIMER B: fully time-programmable cycle phases with programmable heating time and optional temperature control
TIMER C: fully time-programmable cycle phases, heating programmable with two times and two power levels
SYNCHRONISED: as TIMER A with holding time synchronised by an external event
FULL AUTO: as TIMER A, with management of the automatic solder wire feeder
FULL AUTO 2 WIRES: as Full auto, with the possibility of applying two independent solder wire feeders at the same soldering point (available only with –TS option)
THERMAL PROFILE: functioning with thermal profile (available only with -TP option)
THERMAL PROFILE 2 WIRES: as THERMAL PROFILE, with the possibility of applying two independent solder wire feeders at the same soldering point (available only with –TS and -TP option)
Control Inputs
2 inputs for the connection of CEIA optical temperature sensors
2 insulated digital inputs for connecting the cycle activation pedals
2 insulated digital inputs for halting the operating cycle
4 0-10V (or 0-20 mA, or 4-20mA) inputs (2 used for power control and 2 for temperature control)
2 insulated inputs (RS232) for connection to external programmable units
1 plug for a Field Bus module (accessory)
6 insulated auxiliary digital inputs
2 solder wire dispenser encoder inputs
2 “wire present” inputs
2 insulated digital inputs for starting a special cycle in manual mode
Outputs for Activation of External Slave Devices
2 serial outputs for connecting and managing two independent Power Cube generators
2 outputs for activation of antioxidant gas diffusers
2 outputs for “Generator ON” signals
2 outputs for “Temperature reached” signals
2 outputs for activation of rapid cooling gas diffusers
2 outputs for “End of cycle” signals
2 output for system ready signal (relay output)
2 0-10V (or 0-20 mA, or 4-20mA) outputs for temperature reading
2 0-10V (or 0-20 mA, or 4-20mA) outputs for power reading
2 solder wire dispenser driver outputs
2 auxiliaries open collector outputs
Self-Diagnosis
Check of temperature and on the cooling water presence
Correct inductor dimensioning check
Internal malfunction
Working cycle malfunction
Reading/writing malfunction of internal memory cells
Inductor short circuit
Reading/writing malfunction of Program Card memory cells
Power Cube missed connection
Generators parameter screenshot
Supply voltage too low
Supply voltage too high
Soldering wire presence
Phase missing (if connected to 90, 180, 360 and 720 Power Cube Generators)
Programming access control through a password
Internal Memory
100 sets of working parameters
100 different storable thermal processes made of up to 20 segments per process (TP versions)
Removable Data Flash Card
100 sets of working parameters storable on each card
100 different storable thermal processes made of up to 20 segments per process (TP versions)
Power Supply and Power
Power supply voltage: 195-255 Vac, 1~ 50/60 Hz
Maximum absorbed power: 60 W
Operating Conditions
Operating temperature: + 5 to + 55 °C
Storage temperature: - 25 to + 70 °C
Relative humidity: 0-95% (without condensation)
Container
Stainless steel construction
Dimensions (WxDxH): 275 mm x 265 mm x 140 mm
Weight: 6 kg
Safety Features
Insulation from the mains voltage
Low operating voltage; no risk for the operator
Complies with international standards currently applicable for Electrical Safety (EN 60204-1) and Electromagnetic Compatibility (EN 61000-6-2, EN 61000-6-4)