| Power Cube 32/400 | Power Cube 45/400 |
Power Supply and Power | Input current | 13A max - external conductors ø2.5 min. | 16A max - external conductors ø4 min. |
Average power at inductor | 32 kVAR | 45 kVAR |
Maximum absorbed power | 2.8 kW | 3.5 kW |
Supply voltage | 180 ÷ 260 Vac, monophase - 50/60 Hz |
Frequency Range | 375 kHz... 575 kHz |
Cooling | Water cooling | Pressure: 300 kPa |
Water flow for each connected head | From 1.5 to 2 l/min |
Control Inputs | RS232 serial interface | 1 RS232 asynchronous serial port for connection with external PLC or Controller |
Digital input activator | 2 isolated digital inputs for the cycle activation switches |
Analogue power adjustment input | 2 analog inputs for output power control (optional) |
Operating Conditions | Operating temperature | + 5 °C to + 55 °C |
Storage temperature | - 25 °C to + 70 °C |
Relative humidity | 20-95% (without condensation) |
Dimensions (WxDxH) | Generator | 275 mm x 265 mm x 140 mm | 275 mm x 265 mm x 140 mm |
Heating head HH10/HH11 | 62,5 mm x 123 mm x 95 mmm | 62,5 mm x 123 mm x 95 mm |
Miniaturized heating head HH15 | 52 mm x 107 mm x 77 mm | 52 mm x 107 mm x 77 mm |
Standard inductor holder | 150 mm | 150 mm |
Weight | Generator | 10 kg | 10 kg |
Heating head | 2 kg | 2 kg |
Conformity | Complies with international standards currently applicable for Electrical Safety (EN 60204-1, EN 60519-1, EN 60519-3) and Electromagnetic Compatibility (EN 55011, EN 61000-6-2) |